Inverpack inverter system
INVERTER SYSTEM
Highly Effective Protection of Critical Loads on Unstable AC Power The Inverpack inverter system can help reduce system acquisition and installation costs through its compact design and cost-effectiveness. The system provides high quality uninterruptible power supply to the AC load.


MAIN CHARACTERISTICS
- High power density
- Pure sine wave 50Hz
- Hot swap
- Wide operating temperature range
- Modular design, provides fast expansion (increase) of capacity and redundancy (increase in reliability) N+1...N+n
- Built-in fast acting electronic static switch - bypass
- Intelligent Controller and WinPower software for system management and remote monitoring
The Inverpack Inverter Module is the basic building block for building modular Inverpack inverter systems. By using the controller, the STS static switch and the manual bypass AC distribution box, inverter systems can be built in a wide output power range from 2 kVA to 12 kVA, without STS up to 24 kVA.
The inverter module Inverpack 1000 converts DC current from a 48V nominal voltage source into a pure sine wave f = 50Hz and a controller-regulated output voltage of 208/220/230/240V AC.
An electronic static bypass switch allows instantaneous switching of power up to 12 kVA between the inverter output and the mains without interrupting the power supply to the load. For this, the system uses a separate 1U shelf with an STS module and a controller.
The user-friendly controller interface and intuitive PC software (web interface) make it easy to manage all major system functions.
1U shelves with inverter modules are designed for installation in 19 '' cabinets or cabinets, and allow the user to easily create systems with an output power from 2 kVA to 24 kVA, and in the case of using a static bypass key from 2 kVA to 12 kVA.
TECHNICAL CHARACTERISTICS OF INVERPACK INVERTER SYSTEM
Input | |
| Voltage | 40.5-58V (nominal 48V DC) Low voltage warning: 45V Low Voltage Shutdown: 40V High Voltage Warning: 58V High voltage shutdown: 60V |
| Input current | Max working current 23A (DC) Max starting current 46A (DC) |
| Input protection | Reverse polarity protection |
Output | |
| Voltage | 110V version: 110/115 / 120V alternating current 220V version: 208/220/230 / 240VAC Programmable from the controller |
| Frequency | 50/60 Hz, programmable from the controller |
| Waveform | Pure sine wave |
| Power | 1000VA |
| Power factor | 0.8 |
| Harmonic distortion | Not more than 3% |
| Overload capacity | 125% continuous (when controlling the temperature inside the module) 150% up to 20 seconds, then shutdown |
| Dimensions (WxDxH) | 215 х 278 х 44 мм (1U) |
| Load current sharing unit with manual bypass | At the entrance: 6 terminal blocks and bus (-) Output: 9 double-pole circuit breakers MBC 5-position rotary |
STS 112 bypass | |
| Voltage | Universal range of input and output voltage (110V / 220V ac) |
| Switching time | 1/4 cycle (less than 5ms) |
| Working hours | Programmable operating mode (online/offline) |
Inverpack controller | |
| Features | Simple user interface 5 programmable alarm output relays (dry contacts) Multilingual (Russian language is not provided yet) Real time clock LED and sound signaling of alarms |
| Remote access interface | USB, RS232, RS485, optional module RS232/TCP IP |
System information | |
| Working temperature | from -20 to + 70 °C |
| Storage temperature | from -40 to + 85 °C |
| Humidity: | Operation: 5% to 95% non-condensing Storage: 0% to 99% non-condensing |
| Acoustic noise | Not more than 55dB (one module) |
Standard compliance | |
| Electrical protection | IEC 60950-1 UL 60950 CSA 22.2 |
| Electrical magnetic compatibility | EN 61000-6-1 (immunity, industry) EN 61000-6-2 (immunity, industry) EN 61000-6-3 (emission, light industry) EN 61000-6-4 (emission, industry) |
| Ecology | ETSI EN 300 019-2 ETSI EN 300 132-2 RoHS |